Sales Department
+7 8162 765 660
+7 8162 765 665


RGA12

This is a low-current, electromagnetic, monostable, not polarized, not hermetic, high-frequency reed relay with one make contact, designed for switching DC electrical circuits with switching frequency to 100Hz and 5W power and AC electrical circuits with frequency from 400 to 1000MHz and 2,5W power at terminated resistance load 50 Ohm; manufactured in accordance with state standard 16121-86 and ИДЯУ.647613.036 ТУ.

Environmental ratings: cold temperate and humidity conditions.

How to order: Relay RGA 12 ИДЯУ.647613.036-01  ИДЯУ.647613.036 ТУ..

Technical Parameters

Table 1

Type

Model

Rated voltage, V

Operate voltage, V, not more

Release voltage, V, not less

Coil resistance, Ohm

RGA12

ИДЯУ.647613.036

5 ±0,5

3,5

0,5

200±20

ИДЯУ.647613.036 -01

12 ±1,2

8,4

1,1

650±65

RGA12В

ИДЯУ.647613.036 -02

5 ±0,5

3,5

0,5

200±20

ИДЯУ.647613.036 -03

12 ±1,2

8,4

1,1

650±65

Switching Modes

Table 2

Switching range  

Switching power, W, not more

Form of load

Current type  

Switching frequency, Hz  

Number of switching cycles

Value 95% of gamma-resource, not less  

I, А 

U, V 

t=85°С 

from 0,1·10-5
to 1,5·10-4

from 0,5·10-1
до1·10-1

5

Active

Const

100

2,5·106

1,25·106

0,5·107

Св 1,5·10-4
to 0,1·10-1

Св 0,1
to 36

0,1·107

0,5·106

0,2·107

Св 0,1·10-1
to 0,25

Св 1,0
to 90

0,1·106

0,5·105

0,2·106

Св 0,1·10-5
to 0,25

from 0,5·10-1
to 20

2,5

Terminated resistance load , 50 Ohm

var
400 – 1000 MHz

0,1·106

0,5·105

0,2·106

 

Schematic Circuit Diagram

Terminal Position

External Dimensions

Technical Specifications

Table 3

Contact resistance, Ohm, not more

0,3

Maximal switching voltage, V

90

Maximal switching current, A

0,25

Operate/release time, ms, not more

0,8/0,3

Insulation Resistance between relay circuits, mOhm, not less
 - at normal ambient temperature
 - at maximal operating temperature
 - at a higher humidity, frost-dew, dew
 - in conditions of salt fog, mold fungi, static dust (Model B)

        1000
100
10
5

Relay insulation strength (effective value),V
between open contact:
 - at normal ambient temperature
 - at a higher humidity, frost-dew, dew
 - at a lower atmospheric pressure
 - in conditions of salt fog, mold fungi, static dust (Model B)
between contacts and coil:
 - at normal ambient temperature
 - at a higher humidity, frost-dew, dew
 - at a lower atmospheric pressure
 - in conditions of salt fog, mold fungi, static dust (Model B)
between contact and shield:
 - at normal ambient temperature
 - at a higher humidity, frost-dew, dew
 - at a lower atmospheric pressure
 - in conditions of salt fog, mold fungi, static dust (Model B)
between coil and shield
 - at normal ambient temperature
 - at a higher humidity, frost-dew, dew
 - at a lower atmospheric pressure
 - in conditions of salt fog, mold fungi, static dust (Model B)

 

130
100
130
100

          500
300
250
250

200
180
150
150

200
180
150
150

Electric capacity of open contacts, Электрическая емкость разомкнутых контактов, пФ, not more

0,5

 

 

VSWR, from 400 to 1000 MHz, not more

1,8

Damping factor of open/closed contacts, dB, not more

20/3

Weight, g, not more

1,5

Switching wattage of high frequency signal, W, not more

2,5

Time of continuous live coil standing at maximal ambient temperature, h

 - ИДЯУ.647613.036 - 00,-02
 - ИДЯУ.647613.036 –01,-03

 

1000
10000

Total time of continuous live coil standing at maximal ambient temperature, h
 - ИДЯУ.647613.036 -00,-02
 - ИДЯУ.647613.036 –01,-03

 

5000
50000

Operating Conditions

Table 4

Ambient temperature, °С

from minus 60 to plus 85

Atmospheric pressure, Pa, (mm of Mercury)

6,7·102…3,0·105 (5…2280)

Relative air humidity at 35 °С, %

to 98

Vibration loads:
over  1 to 2000 Hz


With acceleration amplitude 200 m/sec2 (20g)

Shock loads
 - Single shocks, duration 2±0,1 мс
 - Multiple shocks, duration 10±2 мс


9 shocks with acceleration to 5000 m/sec2 (500g)
4000 shocks with acceleration to 400 m/sec2 (40g)