RDV11
Is a static time relay in hermetic metal-can package with one NOC terminal, designed for switching DC electrical circuits with fixed time intervals from 0,05 to 7200 seconds, manufactured in accordance with state standard ГОСТ 16120-86 and ЯЛ4.544.003 ТУ, applied in control -and supervision systems of special and general industrial purposes.
Environmental ratings: humidity conditions.
How to order: Time relay RDV 11 ЯЛ4.544.003-01 ЯЛ4.544.003 ТУ
Технические Parameterы
Table 1
Package type |
155.15-2 |
Dimension (with terminals), mm L x W x H |
30х20х5(13) |
Switching current, A |
0,4 |
Switching voltage, V |
4,5 – 80 |
Residual voltage on the unsealed relay (at -60ºC), V, not more |
0,8 (1,5) |
Leakage current of an unsealed relay (at 85ºC),mA, not more |
0,2 (1,5) |
Operating voltage, V |
|
Consumption current, mA, not more |
15 |
Recovery time, ms , not more |
50 |
Delay time, sec. |
0,05;0,1;0,2;0,3;0,35;0,5;0,75;1;1,5;2;3;4;5;7;8;10;20;30;40;45;50;60;90;120;150; 180;240;300;360;480;600;900;960;1200;1800;1920;2400;3600;7200 |
Mean life, a derated operation hour, h (T≤55°C, I≤0,2A, U≤40V) |
25000 50000 |
Temperature, ºC |
from minus 60 to plus 85 |
Humidity, % |
98 at 35°С |
Pressure, Pa |
1,03•102 ÷ 3•105 |
Vibration loads, Hz/g |
1 - 3000/20 |
Shock resistance, g |
500 |
Weight, g, not more |
12 |
Models
Table 2
Model |
Delay time, sec. |
Model |
Delay time, sec. |
Model |
Delay time, |
1 |
2 |
3 |
4 |
5 |
6 |
ЯЛ4.544.003 |
0,05 |
ЯЛ4.544.003 - 19 |
45 |
ЯЛ4.544.003 - 32 |
1800 |
ЯЛ4.544.003 - 01 |
0,1 |
ЯЛ4.544.003 - 20 |
60 |
ЯЛ4.544.003 - 33 |
1920 |
ЯЛ4.544.003 - 02 |
0,2 |
ЯЛ4.544.003 - 21 |
90 |
ЯЛ4.544.003 - 34 |
2400 |
ЯЛ4.544.003 - 03 |
0,3 |
ЯЛ4.544.003 - 22 |
120 |
ЯЛ4.544.003 - 35 |
3600 |
ЯЛ4.544.003 - 04 |
0,5 |
ЯЛ4.544.003 - 23 |
180 |
ЯЛ4.544.003 - 36 |
7200 |
ЯЛ4.544.003 - 05 |
1 |
ЯЛ4.544.003 - 24 |
240 |
ЯЛ4.544.003 - 37 |
150 |
ЯЛ4.544.003 - 06 |
2 |
ЯЛ4.544.003 - 25 |
300 |
ЯЛ4.544.003 - 38 |
0,35 |
ЯЛ4.544.003 - 07 |
3 |
ЯЛ4.544.003 - 26 |
360 |
ЯЛ4.544.003 - 39 |
1,5 |
ЯЛ4.544.003 - 08 |
5 |
ЯЛ4.544.003 - 27 |
480 |
ЯЛ4.544.003 - 40 |
4,0 |
ЯЛ4.544.003 - 09 |
10 |
ЯЛ4.544.003 - 28 |
600 |
ЯЛ4.544.003 - 41 |
7,0 |
ЯЛ4.544.003 - 16 |
20 |
ЯЛ4.544.003 - 29 |
900 |
ЯЛ4.544.003 - 42 |
8,0 |
ЯЛ4.544.003 - 17 |
30 |
ЯЛ4.544.003 - 30 |
960 |
ЯЛ4.544.003 - 43 |
0.75 |
ЯЛ4.544.003 - 18 |
40 |
ЯЛ4.544.003 - 31 |
1200 |
ЯЛ4.544.003 - 44 |
50 |
Technical Specifications
Table 3
Operating voltage, V |
|
Consumption current, mA, not more |
15 |
Residual voltage at “on”-position, V, not more |
1,5 |
Leakage current of an output circuit at “off”-position, mA: |
|
Switching voltage, V |
4,5-80 |
Maximal switching current, A |
0,4 |
Operate time tolerance, %: |
|
Weight, g, not more |
12 |
Electric Strength and Insulation Resistance
Table 4
Test conditions |
Test voltage, V |
Insulation resistance, MOhm, not less |
Normal ambient temperature |
180 |
200 |
Maximal operating temperature |
- |
20 |
Atmospheric under-pressure |
110 |
- |
A higher humidity, frost-dew and dew, salt fog, mold fungi, static dust |
110 |
10 |
Reliability
Minimal operating time during life limit is not less than 25000 hours; at derated operating conditions not less than 50000 hours.
Minimal storage time in a heated storehouse , as well as being mounted in insulated equipment or in protected SPTA (spare parts, tools and accessories) not less than 15 years.
Minimal operating life limit is not less than 15 years.
Reference value of 95% gamma-percentile life is not less than 40000 hours, in derated operating conditions not less than 80000 hours.
Расположение и наValue выводов |
Вид со стороны монтажа |
|
1 – regulator terminal |
Connection Diagram
Operating voltage supply via electromechanical contacts |
Control of TTL micro output |
|
|
Hooking - up of active load |
Hooking – up of inductive load |
|
|
Operating Conditions
Table 5
Operating Temperature Range , °С |
from minus 60 to plus 85 |
Sinusoidal vibration: |
|
Single mechanical shocks: |
|
Multiple mechanical shocks: |
|
Linear acceleration, m/sec2 (g) |
1500 (150) |
Acoustic noise: |
|
Atmospheric under - pressure, Pa, (mm of Mercury) |
1,3.10-4 (10-6) |
Atmospheric over -pressure, kgf/сm2 |
3 |
Higher relative humidity at 35°С, % |
98 |
Static dust, salt fog, mold fungi, frost-dew and dew. |
In accordance with state standard 16120-86 |