RGK56

This is a low-current, electromagnetic, monostable, not polarized, not hermetic reed relay with one change over magnetic operated contact (sealed contact) MKC-14104 and with an inbuilt diode for dampening of Faraday voltage, designed for switching DC electrical circuits with switching frequency to 10000 Hz;
manufactured in accordance with state standard 16121-86 and ИДЯУ.647613.054 ТУ.
Environmental ratings: cold temperate conditions and B.
How to order: Relay RGK 56 ИДЯУ.647613.054 ТУ.
Technical Parameters
Table 1
Model |
Rated voltage, V |
Operate voltage, V, not more |
Release voltage, V, not less |
Coil resistance, Ohm |
ИДЯУ.647613.054-06 |
3±0,3 |
2,1 |
0,3 |
115±23 |
ИДЯУ.647613.054-01,-07 |
5±0,5 |
3,5 |
0,5 |
200±40 |
ИДЯУ.647613.054-02,-08 |
6±0,6 |
3,7 |
0,6 |
500±100 |
ИДЯУ.647613.054-03,-09,-04,-10 |
12±1,2 |
8,1 |
1,1 |
1000±200 |
ИДЯУ.647613.054-05,-11 |
27±2,7 |
19,0 |
2,7 |
2500±500 |
Switching Modes
Table 2
Switching Range |
Switching power, W, not more |
Form of load |
Current Type |
Switching Frequency, Hz |
Number of Switching Cycles |
Value 95% of recourse, not less |
||
I, А |
U, V |
∑ |
t=85°С |
|||||
5·10-6 -10-2 |
5·10-2 - 5 |
5 |
active and inductive |
Const&Var |
50 |
1,0·106 |
5,0·105 |
2,0·106 |
10-2 -2,5·10-1 |
5 - 36 |
active |
5,0·105 |
2,5·105 |
1,0·106 |
|||
2,5·10-1 - 0,5 |
5 - 60 |
10 |
1,0·105 |
5,0·104 |
2,0·105 |
Technical Specifications
Table 3
Contact resistance, Ohm, not more |
0,3 |
Operate time, ms, not more |
0,5 |
Release time, ms, not more |
2,0 |
Insulation Resistance between relay circuits MOhm , not less |
|
Insulation relay strength (effective value) V |
127 500 |
Weight, g, not more |
2,8 |
Schematic Circuit Diagram |
External Dimensions |
|
|
Operating Conditions
Table 4
Ambient temperature, °С |
from minus 60 to plus 100 |
Atmospheric pressure, Pa, (mm of Mercury) |
6,7·102…3,0·105 (5…2280) |
Relative humidity at 35 °С, % |
to 98 |
Vibration loads: |
|
Shock loads |
|
Linear acceleration, m/sec2 |
to 500 (50g) |