RGK36

This is a low-current, electromagnetic, supersensitive, miniature, monostable, not hermetic SIL reed relay for DC with one make contact, with a lower wattage and a higher reliability, and with an inbuilt diode for dampening of Faraday voltage; designed for switching DC & AC electrical circuits with a frequency to 10000 Hz; manufactured in accordance with state standard 16121-86 and ИДЯУ.647613.014 ТУ.


Environmental ratings: cold temperate conditions and B.


How to order: Relay RGK 36 ИДЯУ. 647613. 014-01    ИДЯУ. 647613. 014 ТУ

Technical Parameters  

Table 1

Тип

Model

Without a diode

With a diode

Rated Voltage V

Operate voltage V (not more )

Release voltage V (not less)

Coil resistance Ohm

RGK 36

ИДЯУ.647613.014

+

-

,

ИДЯУ.647613.014-01 

+ 

-

ИДЯУ.647613.014-02 

+ 

-

ИДЯУ.647613.014-03 

+ 

-

,

ИДЯУ.647613.014-04

+ 

-

,

ИДЯУ.647613.014-05

-

+ 

,

ИДЯУ.647613.014-06

-

+ 

ИДЯУ.647613.014-07

-

+ 

ИДЯУ.647613.014-08

-

+ 

,

 

ИДЯУ.647613.014-09

-

+

,

RGK 36В

ИДЯУ.647613.014-10

+

-

,

ИДЯУ.647613.014-11 

+ 

-

ИДЯУ.647613.014-12 

+ 

-

ИДЯУ.647613.014-13 

+ 

-

,

ИДЯУ.647613.014-14

+ 

-

,

ИДЯУ.647613.014-15

-

+ 

,

ИДЯУ.647613.014-16

-

+ 

ИДЯУ.647613.014-17

-

+ 

ИДЯУ.647613.014-18

-

+

,

ИДЯУ.647613.014-19

-

+

,

Technical Specifications

Table 2

Contact resistance, Ohm, not more

0,15

Operate time, ms, not more

1,0

Release time, ms, not more     

0,5

Insulation Resistance between relay circuits MOhm , not less

 - at normal ambient temperature
 - at maximal operating temperature
 - at a higher humidity, frost-dew, dew, salt fog,
 - mold fungi, static dust (climate model B)

 

1000
100
10
5

Insulation relay strength (effective value) V

 - at normal ambient temperature
 -at a higher humidity, frost-dew, dew
 - at atmospheric under-presssure
 - in conditions of salt fog, mold fungi, static dust

Between relay circuits
500
300
150
200

Between contacts

180
110
110
110

Weight, g, not more

2,6

Switching Modes

Table 3

Switching Range

Current Type

Form of load

Switching Frequency, Hz

Number of Switching Cycles

I, А

U, В

t=70°С

5·10-9 - 0,01

10-5- 6

const and
var

active

100

108

5·107

0,01 - 0,05

6-100

50

107

5·106

0,05 - 0,1

6-100

20

5·106

2,5·106

0,1 - 0,5

6-20

10

5·106

2,5·106

 

Schematic Circuit Diagram

Mounting Dimensions

-00…-04, -10,…-14

-05,…-09,-15,…-19

All models

Operating Conditions

Table 4

Ambient temperature, °С

from minus 50 to plus 70

Relative humidity at temperature not more than 35° С,

to 98%

Atmospheric pressure, Pa, (mm of Mercury)

6,7·102…3,03·104  (5…2280)

Sinusoidal vibration of:                      
 - over 1 to 50Hz
 - over 50 to 2000Hz


With motion amplitude 1,5mm
With acceleration amplitude 200 m/sec2 (20g)

Mechanical shocks:
 - Single shocks with duration (0,1-2 мс)
 - Multiple shocks with duration (2-10 мс)


9 with acceleration to 500 m/sec2 (50g)
10000 with acceleration to 400 m/sec2 (40g)