RGK15

This is an electromagnetic, neutral, monostable reed relay for DC (direct current) with two magnetic operating contacts MKA 20101, designed for switching of DC & AC electric circuits, manufactured in accordance with state standard 16121-86 и Бг0.450.003 ТУ.
Environmental ratings: cold temperate conditions: 2.1
Ordering data: RGK15 Бг4.569.003-01 Бг0.450.003 ТУ.
Technical Parameters
Table 1
Model |
Coil Resistance Ohm |
Operate Voltage V (not more) |
Release Voltage V (not less) |
Rated Voltage V |
Бг4.569.003 |
155±15 |
3,6 |
1,5 |
5±0,5;6±0,6 |
Бг4.569.003-01 |
650±65 |
7,2 |
1,5 |
12±1,2 |
Бг4.569.003-02 |
2400±240 |
14,4 |
1,5 |
24±2,4 |
Бг4.569.003-03 |
2400±240 |
14,4 |
1,5 |
|
Technical Specifications
Table 2
Operate time, ms, not more |
1,5 |
Release time, ms, not more |
0,5 |
Contact Resistance Ohm (at V=(6±1)V and I= (10±1)mА) |
0,2 |
Insulation Resistance between relay circuits MOhm |
|
Test Voltage of AC (effective value) V : |
500 300 180 |
Weight, g, not more |
8,5 |
Switching Modes
Table 3
Switching range |
Current type |
Form of Load |
Switching Frequency, Hz |
Number of switching cycles |
||
I, А |
U, В |
∑ |
t=85°С |
|||
0,5·105-,1·10-2 |
0,05-30 |
const & var
|
active |
100 |
9·107 |
1,8·107 |
0,01-0,01 |
0,05-30 |
9·106 |
4,5·106 |
|||
01,-0,25 |
0,05-30 |
9·105 |
4,5·105 |
|||
0,02-0,03 |
150-180 |
9·105 |
4,5·105 |
|||
0,001-0,01 |
0,05-30 |
9·106 |
4,5·106 |
|||
0,01-0,1 |
0,05-30 |
Const |
inductive |
10 |
105 |
5·104 |
0,1-0,2 |
0,05-30 |
5·104 |
2,5·104 |
Schematic Circuit Diagram |
External and Mounting Dimensions |
|
|
Operating Conditions
Table 4
Ambient temperature, °С |
from minus 60 to plus 85 |
Atmospheric pressure, Pa (mm of Mercury) |
8,4·104… 3,03·105 (from 6,3·102 …2,3·103) |
Relative humidity at 35 °С, % |
to 98 |
Vibration loads |
|
Линейные центробежные) нагрузки |
to 981 m/sec2 (100g) |
Shock loads: |
|