Sales Department
+7 8162 765 660
+7 8162 765 665


RPA11

This is a low-current, electromagnetic, hermetic, polarized, bistable, two-position, high-frequency relay with one change-over contact, designed for switching DC & AC electrical circuits with frequency to 150 MHz; manufactured in accordance to State standard 16121-86, State standard ВД 16121-86 and Бг0.450.000 ТУ.

Environmental ratings: cold temperate, cold and humidity climate 2.

How to order: Relay RPA11 Бг4.521.014-01  Бг0.450.000 ТУ.

Technical Parameters

Table 1

Type

Model

Contact resistance, Ohm, not more

Coil resistance, Ohm

Operate time, ms, not more

Operate amperage, A, not more

Rated voltage, V

RPA 11

Бг4.521.014

1,5

280±28

5

0,026

13±1,3

Бг4.521.014-01

0,1

1100±165

5

0,013

27±3

Бг4.521.014-02

1,5

280±28

5

0,026

13±1,3

Бг4.521.014-03

0,1

1100±165

5

0,013

27±3

RPA 11В2

Бг4.521.016

1,5

280±28

5

0,026

13±1,3

Бг4.521.016-01

0,1

1100±165

5

0,013

27±3

Бг4.521.016-02

1,5

280±28

5

0,026

13±1,3

Бг4.521.016-03

0,1

1100±165

5

0,013

27±3

Technical Specifications

Table 2

Insulation resistance between current conductors, between current conductors and package, megOhm:
 - at normal ambient temperature
 - At max. temperature

 

500
20

Test voltage (effective value) between current carrying elements, between current carrying elements and package, V:
 - at normal ambient temperature
 - In conditions of a higher humidity
 - at atmospheric under-pressure

 

500
300
180

Attenuation in the live contact circuit when switching power is 1 to 24 W, percentage of throughput, not more


2

Capacitance, pf, not more:
 - between open contacts
 - between contacts and package


1
2

Insulation resistance in conditions of a higher humidity and frost-dew nip, megOhm, not less:
 - between contacts and coil, between contacts and package, between contacts
 - between coil and package

 

10
5

Weight, g, not more

20

Switching Modes

Table 3

Model

Switching range

Current type

Form of load

Switching frequency, Hz, not more

Number of switching cycles

I,А

U,V

Σ

При

t= 100°С

Бг4.521.014

0,2-0,8

6-30

Const&Var
(to 150МHz)

Active

10

105

5·104

Бг4.521.014-01

10-6-10-5

0,05-1

Бг4.521.014-02

0,2-0,8

6-30

Бг4.521.014-03

10-6-10-5

0,05-1

Бг4.521.016

0,2-0,8

6-30

Const&Var
(to 150МHz)

Active

10

105

5·104

Бг4.521.016-01

10-6-10-5

0,05-1

Бг4.521.016-02

0,2-0,8

6-30

Бг4.521.016-03

10-6-10-5

0,05-1

 

Schematic Circuit Diagram

External Dimensions

Operating Conditions

Table 4

Ambient temperature, °С

from minus 60 to plus 100

Atmospheric pressure, kPa, (mm of Mercury)

1,33·10-6 – 3,03·105 (10-5 - 2280)

Relative humidity at 35 °С, %

to 98

Sinusoidal vibration:
 - over     5 to   50 Hz
 - over   50 to  600 Hz
 - over 600 to 2500 Hz


with amplitude 1,5 mm
shocks with acceleration to 147 m/sec2   (15 g)
shocks with acceleration to 98,1 m/sec2  (10 g)

Shock loads:
 - single shocks
 - multiple shocks


9 shocks with acceleration 1470 m/sec2  (150g)
or 10000 at acceleration to 343 m/sec2  (35g)

Linear loads    

to 490 m/sec2 (50g)