This is an electromagnetic, high frequency, not hermetic, polarized relay with coaxial terminals and one change-over contact; designed for switching DC & AC electrical circuits with frequency to 500 МHz when power is to 24 W and with frequency to 1000 МHz when power is to2W.
Environmental ratings;cold temperate and cold climate.
Type models: bistable - RPV 5/4; monostable - RPV 5/7.
How to order: Relay RPV 5/7 РС4.521.322 Бг0.452.002 ТУ.
Technical Specifications
Table 1
Rated voltage, V |
27±3 |
Coil resistance, Ohm |
1100±165 |
Operate current strength, mA, not more |
13 |
Release current strength, (for relay RPV 5/7), mА, not less |
2 |
Operate time, ms, not more |
5 |
Release time, ms, not more |
3 |
Electric capacitance, pf, not more: |
2 |
Insulation resistance, MOhm, not less: at normal climatic ratings: - between contacts |
500 20 10 |
Test voltage (effective value) between current carrying elements, between current carrying elements and package, V: |
500 |
Contact resistance, Ohm, not more: |
|
Coupling attenuation on terminals and contact system, percentage of throughtput, not more: |
1 |
Relative pulse ratio of coil power supply during periodic switching-on |
1,5-3 |
Weight, g, not more |
30 |
* Relay type RPV 5/4 has the following models РС4.521.324 and РС4.521.325; Relay type RPV5/7 — РС4.521.322, РС4.521.323 and РС4.521.326
They can switch high-frequency, active termination when circuit characteristic impedance is 50 or 75 Ohm.
Table 2
Frequency, MHz |
200 |
300 |
400 |
500 |
600 |
800 |
1000 |
VSWR |
1,35 |
1,45 |
1,50 |
1,60 |
1,80 |
1,82 |
1,95 |
Switching Modes
Table 3
Switching range |
Form of load |
Current type |
Switching frequency, Hz, not more |
Number of switching cycles |
||
I, A |
U, V |
∑ |
t°=100°C |
|||
РС4.521.323 (contact 1-2); PC4. 521.325;PC4.521.326 |
||||||
10-6-10-5 |
0,05-1 |
Active |
Const & Var (to 1000 MHz) |
10 |
105 |
2•104 |
10-5-10-4 |
0,5-10 |
|||||
0,0001-0,2 |
2-30 |
Const & Var (to 500 MHz) |
||||
0,005-0,06 |
2-30 |
Inductive t≤50 ms |
Const |
5 |
0,5•105 |
1,25•104 |
0,0001-0,1 |
2-30 |
Inductive cos f≥0,3 |
Var 50-1000 MHz |
1 |
105 |
2•104 |
0,05-0,15* |
2-30 |
Inductive t≤15 ms |
Const |
1 |
0,2•105 |
0,5•104 |
РС4.521.322; PC4. 521.323 (contact 2-3);PC4.521.324 |
||||||
0,2-0,8 |
6-30 |
Active |
Const & Var (to 500 MHz) |
10 |
105 |
2•104 |
0,1-0,2 |
30-110 |
Const & Var (to 1000 MHz) |
||||
0,05-0,1 |
110-250** |
|||||
0,05-0,4 |
6-30 |
Inductive t<15 ms |
Const |
10 |
0,5•105 |
2,5•104 |
0,1-0,4 |
6-30 |
Inductive cos φ>0,3 |
Var 50-1000 MHz |
1 |
105 |
2•104 |
* For models РС4.521.325 and РС4.521.326: 0,06—0,15 А.
** At atmospheric pressure from 666 to 53320 Pa (from 5 to 400 mm of Mercury ) the voltage on the contacts is not more than 120V AC or 170V DC
Schematic Circuit Diagram |
External Dimensions |
|
|
Operating Conditions
Table 4
Ambient temperature, °С |
from minus 60 to plus 100 |
Atmospheric pressure, Pa, (mm of Mercury) |
6,6•102... 2,1•105 (5…1,6•103) |
Relative humidity at 35 °С, % |
to 98 |
Vibration loads: |
|
Shock loads: |
|
Shock resistance |
at acceleration to 343 m/sec 2 (35g) |
Linear loads |
|