Sales Department
+7 8162 765 660
+7 8162 765 665


RPS47

This is a low-current, electromagnetic, polarized, hermetically sealed, two-position relay with four change-over contacts;

designed for switching DC electrical circuits with frequency to 10000 Hz;

manufactured according to GOST 16121-86 and ЯЛО.452.093 ТУ.

Environmental ratings: humid conditions.

Ordering data: Relay RPS 47 РС4.520.764 ЯЛО.452.093 ТУ

Technical Parameters

Table 1

Type

Model

Rated voltage, V

Coil Resistance I and II, Ohm

Operate Voltage in Delivery Time, V

RPS 47

РС4.520.764

15

200±40

5,0 – 8,2

RPS 47Т

РС4.520.765

RPS 47

РС4.520.765-01

24; 27

400±80

7,2 – 12,2

RPS 47Т

РС4.520.764-01

RPS 47

РС4.520.764-02

27

740±148

9,0 – 15,0

RPS 47Т

РС4.520.765-02

Technical Specifications

Table 2

Operate Time, ms, not more

5

Contact Resistance of Electrical Circuit when Voltage = (6±1)V and amperage =(10±1)mА, Ohm, not more          

0,25

Dielectric Strength between Current Carrying Circuits (effective value), V

 - at normal ambient temperature
 - at high humidity, silver thaw, dew 
 - at atmospheric under-pressure 
 - in conditions of salt fog and mold & fungi, static dust (climate model T)    

 

220
150
150
150 

Dielectric Strength between Current Carrying Circuits and Package (effective value),V

 - at normal ambient temperature
 - at high humidity, silver thaw, dew 
 - at atmospheric under-pressure 
 - in conditions of salt fog and mold & fungi, static dust (climate model T)

 

220
150
150
150

Dielectric Strength between Coil and Package (effective value), V

 - at normal ambient temperature
 - at high humidity, silver thaw, dew 
 - at atmospheric under-pressure 
 - in conditions of salt fog and mold & fungi , static dust (climate model T)

 

300
180
180
180

Insulation Resistance between Electrical Circuits, mOhm, not less:

 - at normal ambient temperature
 - at maximal operating temperature

In Conditions of High Humidity, Silver Thaw, Dew:
 - between coils and package
 - between electrical circuits and package
in conditions of salt fog and mold & fungi , static dust (climate model T)
 - between coils and package
 - between electrical circuits and package

 

200
20


5
10

5
10

Weight, g                       

12

Switching Modes

Table 3

Switching Range

Form of load

Current type 

Switching Frequency,Hz,
not more 

Number of switching cycles

I,А

U,V

t=+125°C

5·10-6 ÷ 10-3

0,05 ÷  10

Active

Var & const

5*

105

0,5·105

10-3 ÷  0,1

0,5 ÷  36

Active

Const

5*

105

0,5·105

10-2 ÷  1,0

6 ÷  36

Active

Const

5*

105

0,5·105

10-2 ÷  0,15

1,2 ÷  60

Active

Var ≤1100Hz

3*

5·103

2,5·103

5•10-3 ÷ 0,15

1,2 ÷  36

Inductive τ <0.005 c

Const

5*

105

0,5·105

0,15 ÷   0,5

1,2 ÷  36

Inductive τ <0.005 c

Const

1

5·103

2,5·103

0,05 ÷  0,25

1,2 ÷  36

Inductive τ <0.015 c

Const

1

104

0,5·104

1,0 ÷   1,5

6 ÷  30

Active

Const

1

2·103

-------

* At ambient temperature over 100°С the switching frequency is not more than 1Hz

Schematic Circuit Diagram

External and Mounting Dimensions 

Operating Conditions

Table 4

Ambient temperature, °С

from minus 60 to plus 125

Relative humidity at t ≤ 35°С, %

to 98

Sinusoidal Vibration:
 - over  0,5 to 10Hz
 - over     10 to 50Hz
 - over     50 to 3000Hz
 - over 3000 to 4000Hz
 - over 4000 to 5000Hz

with amplitude to 3,5 мм
with amplitude to 2 мм              
with acceleration to 200 m/sec2 (20g)
with acceleration to 350 m/sec2  (35g)
with acceleration to100 m/sec2 (10g)

Atmospheric pressure, Pa, (mm of Mercury)

13·10-5…297193 (10-6…2280)

Shock loads:

 - single shocks duration 0,1-2 мс

 - single shocks duration 1-5 мс

 - multiple shocks duration 1-5 мс

 - multiple shocks duration 2-10мс 



3 with acceleration to 5000 m/sec2 (500g)

9 with acceleration to 1500 m/sec2 (150g)

4000 with acceleration to 750 m/sec2 (75g)

10000 with acceleration to 400 m/sec2 (40g)

Shock resistance

shocks with acceleration to 1000 m/sec2 (100g)